For laboratory research use only. Every lot independently tested; certificates published by lot.

Melanotan II testing and quality control

Every lot of Melanotan II is tested by Freedom Diagnostics, an independent laboratory, for purity, identity and net content before release. Endotoxin and microbial results are added where those tests are run. Here is what each test measures, how results are reviewed, and how to check them yourself.

Last updated

99.90%
Purity, current lots
≥95%
Release specification
LC-MS
Identity method, every lot
Independent
Third-party laboratory

The three methods

No single method answers every question about a peptide sample. Melanotan II is tested with complementary methods so that each one covers what the others can't.

HPLC-UV purity

Answers: how much of the sample is the main compound?

Reversed-phase high-performance liquid chromatography separates the sample's components by hydrophobicity, and a UV detector records each as a peak. Purity is the main peak's area as a percentage of all detected peak area.

Limits: does not identify the peak, and impurities that co-elute or absorb weakly in UV can be under-counted. More on HPLC

LC-MS identity

Answers: is the main compound Melanotan II?

The separated sample enters a mass spectrometer via electrospray ionization, which gives the molecule one or more charges. The observed ions, near m/z 1025 (1+) and 513 (2+), are matched against values calculated from Melanotan II's molecular weight of 1024.18.

Limits: confirms molecular weight, not amino-acid order.

Net content

Answers: how much MT2 is in the vial?

The laboratory quantifies the main compound in the tested vial against a standard. It is reported in milligrams next to the labeled vial size.

Limits: measured on the vial tested; other vials from the same lot are expected to be similar but are not individually measured.

Quality-control process

The path every lot follows from production to a published certificate.

  1. Lot assignedA lot number is assigned and printed on every vial label.
  2. Sample sentVials from the lot go to Freedom Diagnostics, an independent lab.
  3. AnalysisHPLC-UV purity, LC-MS identity and net content, plus endotoxin and PCR where listed.
  4. ReviewResults are compared with the stated specification: ≥95% purity, identity confirmed.
  5. PublishedThe lot record and certificate PDF are posted at /coa/ under its lot number.
  6. VerifiableAnyone can look the lot up at /verify/ and confirm it with the laboratory.

Release specification

MT2 Research Supply’s stated release specification is ≥95% HPLC-UV purity with identity confirmed by LC-MS. Current lots test at 99.90%, well above the ≥95% release specification.

Batch identification

Each lot carries a unique lot number (for example KB32432) printed on every vial label and on the certificate. The laboratory also assigns its own reference numbers (accession number and search code), which are listed on each lot page for cross-checking.

Document retention

Certificates remain published in the archive after a lot sells through, so the documentation for any vial stays available.

About the laboratory

Freedom Diagnostics is an independent, U.S.-based analytical testing laboratory. Its certificates for Melanotan II are signed by the laboratory's principal chemist and carry a QR code linking to the laboratory's own record.

Laboratory contact: freedomdiagnosticstesting.com, Admin@FreedomDiagnostics.net.

Verify a result

  1. Find the lot number on your vial. It is printed on the label, for example KB32432.
  2. Look it up. Enter it at buymt2.com/verify, or open the matching lot in the COA archive.
  3. Check the lab's own record. Scan the Freedom Diagnostics QR code printed on the certificate, then search for klow.bio under the Company tab to view the laboratory record.
  4. Compare the details. Lot number, the laboratory’s reference numbers, purity and dates should match exactly.

Results across current lots

LotVial sizeNet contentPurity (HPLC-UV) Identity (LC-MS)Endotoxin (LAL)Microbial (PCR)ReportedCOA
KB32432 10 mg 12.33 mg 99.90% Confirmed Not tested Not tested View lot KB32432
KB32432 10 mg 12.33 mg 99.90% Confirmed Not tested Not tested View lot KB32432

Testing laboratory: Freedom Diagnostics. Release specification: purity ≥95% by HPLC-UV with identity confirmed by LC-MS. Results apply only to the lot listed. Certificates list the testing client as Klow.bio / Klow Labs LLC, the company that operates MT2 Research Supply.

Identity

IonCalculationExpected m/zObserved on COAs

Expected values are calculated by MT2 Research Supply from the average molecular weight (1024.18 g/mol; H+ 1.0073, Na+ 22.99, K+ 39.10). Observed values are as printed on each lot's mass confirmation panel.

Purity

HPLC-UV purity by lot. The scale runs from 99.0% to 100% so small differences are visible; every lot shown meets the ≥95% release specification.

What a certificate of analysis does and doesn't show

  • A COA reports the identity, purity and content of the specific sample tested, on its test date. Results apply to that lot only.
  • HPLC purity measures the main peak relative to other detected components. It does not identify the peak on its own; the separate identity test (LC-MS) does that.
  • Mass confirmation matches molecular weight. It does not by itself confirm amino-acid order.
  • Endotoxin and microbial results apply only where those tests appear on the certificate. Lots without them are marked "Not tested".
  • A certificate does not establish stability after the test date or suitability for any particular purpose.

Method guides

Testing questions

How is MT2 analyzed?

Melanotan II is analyzed with complementary methods: HPLC-UV for purity, LC-MS for identity, a quantitative measurement for net content, and, where listed, LAL endotoxin and PCR microbial testing. Results are published per lot at buymt2.com/coa/.

Who tests Melanotan II?

Every lot is tested by Freedom Diagnostics, an independent third-party analytical laboratory. MT2 Research Supply does not test its own material for published certificates.

What purity does Melanotan II test at?

Current lots report HPLC-UV purity 99.90%, against a stated release specification of ≥95%. The most recent result is 99.90% for lot KB32432.

How is the identity of Melanotan II confirmed?

By liquid chromatography–mass spectrometry (LC-MS), performed by Freedom Diagnostics on every lot. LC-MS separates the sample and measures the mass of the main component, confirming it has the molecular weight expected for the compound.

Is Melanotan II tested for endotoxin?

Endotoxin and microbial testing are reported per lot. Every lot page in the COA archive states whether those tests were performed.

What is HPLC testing, and what does the purity percentage mean?

HPLC (high-performance liquid chromatography) separates a sample's components so each appears as a peak. The purity percentage is the main peak's share of all UV-detected peak area. It does not confirm identity (the separate LC-MS test does) or measure the amount of peptide in the vial (net content does).

What is a MT2 COA?

A MT2 certificate of analysis is the testing laboratory's report for one lot: the lot number, test dates, methods and results for purity, identity and net content. MT2 Research Supply publishes every lot's COA as a readable page at buymt2.com/coa/.

Where can I find the COA for my vial?

Find the lot number printed on your vial label and enter it at buymt2.com/verify/, or open that lot in the COA archive at buymt2.com/coa/.

How do I confirm a COA with the laboratory?

Scan the Freedom Diagnostics QR code printed on the certificate, then search for klow.bio under the Company tab to view the laboratory record.

Why is the measured net content different from the vial size?

Net content is the laboratory's measurement of peptide in the tested vial. Current lots measured 12.33 mg in a 10 mg vial, 12.33 mg in a 10 mg vial.

Buy MT2

10 mg vials. Current lot KB32432 tested at 99.90% purity with identity confirmed by LC-MS. Current purchasing is available through Klow.bio.